<LOGO>
FM Transmitter Measurement Report
Created: 2024-08-02 12-44-19
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 58 dBuV SANDELS
Pilot RDS Phase Difference
6.6 kHz 6.2 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
14 kHz 18 kHz 17103 2,3739
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-2,5 dBr 0,15 dBr 3,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 9 --:--
RT
-
AF EON
92.0, 94.7, 98.5, 106.3, 107.5 MHz -
FM Scope Max at: 18 kHz MIN: 14 kHz % above 76 kHz: 2,3739 Acquired: 2024/08/02 12.43.15 Total samples: 17103 Equivalent time: 0:14:15 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: 3,2 dBr MIN: -2,5 dBr AVE: 0,15 dBr % above 12,2 dBr: 0,0 Last value: -1,8 dBr (2024/08/02 12.43.15) 12.30 12.32 12.34 12.36 12.38 12.40 12.42 -2 0 2 4 Pm [dBr]